Genesys Water Treatment Chemicals



Genesys Reverse Osmosis chemicals have been specifically designed to improve the all round performance of Reverse Osmosis Plants enabling them to operate efficiently even in areas where feed waters are challenging.

General details of the products available are as follows. Detailed specifications and application information being available on request:-

Chemical Application Description
Genefloc PWF Flocculont Packaging: 25Kgs Improved performance of RO pre-filtration equipment A general purpose flocculant PoIyDADMAC for use in surface, well and process waters with medium to high SDI values. Genefloc PWF should be dosed continuously to feed water allowing at least 5 minutes contact time before filtrotion. Typical dose rate of Genefloc PWF is 2-5mg/I.
Genesol  20KgPackaging:25kg Reverse Osmosis Powder Membrane Preservative Genesol 20 is a powdered membrane preservative for MF/UF and NF/RO systems. It enables membrane storage in-situ — thus avoiding costly shipping, off site preservation & storage — while also reducing the potential for biological growth in ancillary equipment. Genesol 20 is a safe & elective solution to ensure for long-term preservation of membrane systems without loss of peñormance. Genesol 20 should be used as a 2% solution using permeate only and is to be recirculated for at least l5min before the shutdown. After storage, rinse the membranes for 30 mins with permeate before resuming operation.
 
Genesol 37 Reverse Osmosis Low pH Membrane Cleaning An inorganic strongly acidic cleaner elective for removal of inorgonic scale and iron deposits in Reverse Osmosis and Nano-filtration membrane systems. Genesol 37 is highly elective when used as o l -2% solution and alternately soaked and recycled through the membrane system for l -2hours. At this concentration, its self-adiusting pH ensures highest solubility of iron deposits, inorganic scales and proteinous deposits.
Packaging:25kg
Genesol 38 Reverse Osmosis Low pH Membrane Cleaning An inorganic scale cleaner and iron deposit remover for use in Reverse Osmosis and Nano-filtration membrane systems. Used at the right concentration, its self-adjusting pH ensures highest solubility of iron salts is achieved. Genesol 38 is highly elective when used as a 3-4% solution and alternately soa ked and recycled through the membrane system for 4-6hours.
Packaging:25kg
Genesol 80 Packaging: 25Kgs Reverse Osmosis, Nano-filtration and Ultrafiltrotion Membrane Cleaner - Targets Biofilm A highly effective biofilm cleaner for Reverse Osmosis, Nano-filtration and Ultrafiltration membrane systems.. Biofilm predominantly consists of materials secreted by bacteria under stress. Genesol 80 can be used online as part of the normal membrane CIP procedure at a concentration of 2% v/v. It can also be applied continuously online with a dose rate of 1 0-40mg/I depending on the severity of the biofouling or on intermittent basis every 4-8 hours at l 0-80mg/I to inhibit biofilm formotion and maintain a clean membrane surface.
Genesol 703 Reverse Osmosis High pH Membrane Cleaning A general-purpose cleaner for organic based foulants found in Reverse Osmosis and Nano-filtration membrane systems with particular application in removal of aluminium silicate. It is highly elective at a solution of 1-2% at the maximum allowable pH recommended by the membrane manufacturer and should be alternately soaked and recycled through the membrane system for 4-6 hours. Cleaning with warm solutions is advised for improved efficiency. After cleaning, the membrane system should be thoroughly flushed out until the pH values of the feed and discharge are the same.
Packaging: 25Kgs
Genesol 704 Reverse Osmosis High pH Membrane Cleaning (Microbubble technology) A general-purpose cleaner for a wide range of organic based foulants found in Reverse Osmosis and Nano-filtration membrane systems. Genesol 704 is particularly effective against aluminium silicate, which can be difficult to remove with conventional cleaners. It is also effective against most micro- organisms such as bacteria, fungi and algae. Genesol 704 should be used as a 1-2% solution at the maximum allowable pH recommended by the membrane manufacturer. It should be alternately soaked and recycled through the membrane system for 2-4 hours.
Packaging:25kg
Genesys LF Reverse Osmosis Antiscalant Pre-Treatment A broad spectrum liquid antiscalant for use in Reverse Osmosis and Nano-filtration Systems. It is effective at preventing inorganic scale, particularly calcium carbonate, iron and silica thus reducing the frequency of membrane replacement and cleaning. Genensys LF should be dosed continuously to the feed water upstream of the cartridge filters. Typical dosage rates are 2-5 mg/I.
Packaging:25kg
Genesys SI Reverse Osmosis Antiscalant Pre-Treatment An antifoulant for use in Reverse Osmosis and Nano-filtration systems operation on high silica feed- waters. Genesys Sel is also elective against all common scale forming salts such as calcium carbonate, calcium, barium and strontium sulphate. Genesys SI should be dosed continuously to the feed water upstream of the cartridge filters. Typical dosage rates are 2-5mg/I.
Packaging:25kg
Genesys RC Reverse Osmosis Antiscalant Pre-Treatment A broad spectrum antiscalant and antifoulant for use in small and recycling Reverse Osmosis and Nano-filtration systems with less than 1 00m"/day of feed water flow. Genesys RC is effective at preventing all inorganic scale formation thus reducing the frequency of membrane cleaning and replacement. Genesys RC allows systems to be designed and operated at higher recovery rates. Genesys RC should be dosed continuously to the feed water upstream of the cartridge filter. Typical dosage rates are 7-15mg/I.
Packaging:25kg